UPS ZLPOWER
P/No: RM6KL-C    Rack Mount Online UPS
                        
Application:
UPS ZLPOWER 6KVA True Online (P/No:RM6KL-C) Rack mount High frequency online UPS is specially designed for servers, data-center critical network devices, sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, ATM and so on.
Key Features:
v  True Online Double Conversion technology with advanced Microprocessor Control.
v  PWM Technology with IGBT.
v  LED Indicators display Detailed Real-Time UPS Status and parameters.
v  Set Output Voltage, Frequency parameter and bypass function on the display.
v  Advanced MCU microprocessor control technology, ensure long life reliability.
v  Wide input voltage range, Zero transfer time.
v  Rack mount 19” design to save space.
v  Excellent Protection against over voltage, over load, over current, over charge and so on.
v  Input L and N lines reverse wiring detection, Auto start when AC back.
v  DC start function, Input PFC revise function.
v  Humanization bypass output, can be adjustable.
v  Smart RS232 communication with monitoring software.
v  Intelligent slot available for AS-400 Dry contact and SNMP card Remote control.
v  Strong antijamming capability.
v  Available to work with generators.
v  Lightning, surge, short circuit, Network/fax/modem surge protection.
v  LED/LCD display panel optional.
 
SPECIFICATIONS: 
| 
 Model 
 | 
 RM6KL-C 
 | 
  | 
| 
   
 | 
 Technology 
 | 
 True Online Double Convertion 
 | 
  | 
| 
 Rated Power 
 | 
 VA/W 
 | 
 6KVA/4.8kW 
 | 
  | 
| 
 Input 
 | 
 Phase 
 | 
 Single Phase with Ground 
 | 
  | 
| 
 Nominal Voltage 
 | 
 220/230/240Vac 
 | 
  | 
| 
 Voltage Range 
 | 
 176 ~ 300VAC 
 | 
  | 
| 
 Frequency Range 
 | 
 46 ~ 54Hz 
 | 
  | 
| 
 Power Factor 
 | 
 0.98 
 | 
  | 
| 
 Connection 
 | 
 Terminal 
 | 
  | 
| 
 Output 
 | 
 Phase 
 | 
 Single Phase 
 | 
  | 
| 
 Voltage 
 | 
 110/115/120Vac or 220/230/240VAC ± 1% 
 | 
  | 
| 
 Frequency 
 | 
 46~54Hz  (Line mode) 
 | 
  | 
| 
 50Hz ± 0.5Hz (Line mode) 
 | 
  | 
| 
 50Hz ± 0.5Hz (Battery mode) 
 | 
  | 
| 
 Waveform 
 | 
 Pure Sine Wave 
 | 
  | 
| 
 Overload Capability 
 | 
 105%~150% for 10 minutes., 130% for 1 minutes 
 | 
  | 
| 
 Current Crest Ratio 
 | 
 3:1 
 | 
  | 
| 
 Connections 
 | 
 IEC320 -10A * 4  and Terminal Block 
 | 
  | 
| 
 Bypass 
 | 
 Automatic Transfer 
 | 
 on overload and UPS failure 
 | 
  | 
| 
 Before UPS Power-on 
 | 
 “YES” 
 | 
  | 
| 
 Voltage Range  
 | 
 176~261VAC 
 | 
  | 
| 
 Transfer Time 
 | 
 0 ms; less than 4 ms from inverter to bypass and vice versa 
 | 
  | 
| 
 LCD/LED indicators 
 | 
 Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault 
 | 
  | 
| 
 Audible Alarm 
 | 
 Bypass, On battery mode, Battery low, Overload, Fault 
 | 
  | 
| 
 Communications 
 | 
 RS-232 Serial Interface 
 | 
  | 
| 
 Intelligent Slot; 
 | 
  | 
| 
 OPTIONS:  WEBPOWER SNMP/WEB card, AS400 card or WinPower CMC) 
 | 
  | 
| 
 Network Surge Protection (OPTIONS) 
 | 
 RJ45 I/O port available for network or Fax/Modem 
 | 
  | 
| 
 Environmental 
 | 
 Operating Temperature 
 | 
 0 ~ 40°C 
 | 
  | 
| 
 Operating Humidity 
 | 
 20 ~ 90% non-condensing 
 | 
  | 
| 
 Main Unit 
 | 
 Net Weight (Kg) 
 | 
 18.3 kg UPS 
 | 
  | 
| 
 Dimensions (L x W x H) mm 
 | 
 600 x 482.6 x 130 (3U) 
 | 
  | 
| 
 Battery Pack 
 | 
 Type 
 | 
 External Battery Pack 
 | 
  | 
| 
 Nominal DC Voltage 
 | 
 192VDC 
 | 
  | 
| 
 Battery Numbers & Capacity 
 | 
 Depending on the capacity of external battery packs 
 | 
  | 
| 
 Backup Time (Full load) 
 | 
     Depending on the capacity of external battery packs 
 | 
  | 
|   | 
| 
 Recharge Time 
 | 
 5hrs to 90% 
 | 
  | 
| 
 Charging Current (Max.) 
 | 
 4.2A 
 | 
  | 
| 
 Charging Voltage 
 | 
 216Vdc ± 1V 
 | 
  | 
| 
 Net Weight (Kg) 
 | 
      
 | 
  | 
| 
 Dimensions (L x W x H) mm 
 | 
          
 | 
  | 
* Product specifications are subject to change without further notice.