P/No: HQ2000 – Line interactive UPS with AVR
Application:
The Line interactive UPS is in standby status with batteries being charged in normal AC time. When the power supply unexpectedly shuts down, the built-in inverter will in no time convert the battery output into AC to keep stable power supply. The UPS is generally considered high rate, low noise while running and cost-effective, mostly used in comparably stable environment with a small fluctuation of utility power and lower requirement of power supply quality.
Key Features:The UPS now is widely used in protection of PC in govemment offices, education institutes and SMEs.
v  Micro controller (CPU),
v  Waveform: square wave(battery mode).
v  Wide AVR range.
v  Overload and short circuit protection.
v  UPS Auto on when AC recovery.
v  Off mode charging.
v  Humidity: less than 90%.
v  Smart RS-232 or USB communication port with free download softwave from Internet.
v  Modem/Line Surge Protection: RJ11/RJ12/RJ45.
v  Overload/Over charge/Short-circuit protection.
v  Low battery alarm, LED status display. Auto restart while AC recovery.
SPECIFICATIONS:
| 
 MODEL 
 | 
 HQ2000 
 | 
| 
 Techlonogy 
 | 
 Line interactive  AVR 
(Automatic Voltage Regulator -AVR) 
 | 
| 
 Nominal Capacity 
 | 
 2000VA/1200W 
 | 
| 
 Power Factor 
 | 
 0.6 
 | 
| 
 Input 
 | 
 Voltage Range 
 | 
 110/120 VAC or 220/230/240 VAC 
67-137 VAC or 145~280VAC 
 | 
| 
 Frequency 
 | 
 50/60Hz (Auto - Sensing) 
 | 
| 
 Output 
 | 
 Voltage Range 
 | 
 110/120 VAC or 220/230/240 VAC  ±10% 
 | 
| 
 Frequency 
 | 
 50Hz or 60Hz ±10% 
 | 
| 
 Output Waveform 
 | 
 Simulated Sine Wave 
 | 
| 
 Output Connection 
 | 
 Multi perpose Socket * 3   
 | 
| 
 Transfer time 
 | 
 6 -10 ms 
 | 
| 
 Battery 
ZLPOWER 
 | 
 Type 
 | 
 Sealed free maintenance lead acid battery 
 | 
| 
 Capacity 
 | 
 12V,7AH *4PCS 
 | 
| 
 Recharge Time 
 | 
 12 hrs to 90% of capacity full load discharge 
 | 
| 
 Protection 
 | 
 Auto protect 
 | 
| 
 Back-up time(at a PC load with 15"monitor) 
 | 
 >= 30 minutes 
 | 
| 
 Function 
 | 
 Auto voltage output on AC mode, Auto shutoff if short circuit or overload 
 | 
| 
   
 | 
  | 
| 
 DB-9 port,communication software 
 | 
 Optional RS232, RJ11, RJ45, USB  
 | 
| 
 Protection 
 | 
 AC mode 
 | 
 Fuse 
 | 
| 
 Short circuit 
 | 
 AC 
 | 
 Fuse 
 | 
| 
 Invert mode 
 | 
 Auto protect 
 | 
| 
 Alarm 
 | 
 Alarm 
 | 
 Battery discharge 
 | 
 Alarm beeps every four seconds 
 | 
| 
 Low battery voltage 
 | 
 Alarm beeps every second 
 | 
| 
 Overload 
 | 
 Alarm beeps continuously 
 | 
| 
 Indicator light 
 | 
 Auto adjust 
 | 
 Green lighting: AC mode 
 | 
| 
 Battery Discharge 
 | 
 Red lighting: Battery mode 
 | 
| 
 Environment 
 | 
 Operating temperature 
 | 
 0?~45??? 
 | 
| 
 Operating Humidity 
 | 
 10-90% non-condensing 
 | 
| 
 Noise 
 | 
  | 
| 
 UPS Dimension(L×W×H)mm 
 | 
 470*180*275 
 | 
| 
 Net weight (Kgs) 
 | 
 18 
 | 