1. GW Plus Series AC/Solar charging hybrid off grid inverter.
2. LED/LCD display, Enhanced functions setting via LCD.Man-machine intelligent design.
3. Built-in 40A/60A optional MPPT solar charger controller.
4. Remote external display panel realize remote operation.
5. 5 stages adjustable AC charging current. AC charging also can be closed.
6. AC/DC priority modes can be set.
7. Generator restart signal. (Dry contact).
8. 3 times peak power. Strong loading capacity.
9. Overload, output short-circuit protection.
Model
|
GW Plus4KW
|
GW Plus5KW
|
GW Plus6KW
|
AC Input
|
Nominal Power |
4000W
|
5000W
|
6000W
|
Input Voltage Waveform |
Sinusoidal (utility or generator)
|
Nominal input Voltage |
120/230VAC
|
Low Line Disconnect |
85Vac±4%(Normal) or 80Vac±4% (Wide) for 120V 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230V
|
Low Line Re-connect |
95Vac±4%(Normal) or 85Vac±4% (Wide) for 120V 194Vac±4%(Normal) or 145Vac±4%(Wide) for 230V
|
High Line Disconnect |
136Vac±4%(Normal) or 140Vac±4%(Wide) for 120V 263Vac±4%(Normal) or 263Vac±4%(Wide) for 230V
|
High Line Re-connect |
131Vac±4%(Normal) or 135Vac±4% (Wide) for 120V 253Vac±4%(Normal) or 253Vac±4%(Wide) for 230V
|
Max AC input Voltage |
120V for Max150V / 230V for Max270V
|
Frequency |
50Hz:41-54Hz / 60Hz:51-64Hz
|
AC output
|
Output Voltage Waveform |
Sine wave
|
Power Factor |
0.9~1.0
|
Nominal Output Voltage (V) |
LV:120Vac ±10%rms / HV:230Vac ±10%rms
|
Nominal Output Frequency (Hz) |
50Hz ± 0.3Hz / 60Hz ± 0.3Hz
|
Transfer Time |
20ms(max)
|
Solar charger
|
Rated Charge Current |
60A
|
PV Input Voltage range |
30VDC-55VDC for 24VDC / 60-110VDC for 48V
|
Max.PV open circuit array voltage |
24V for 55Vdc?48V for 110Vdc
|
Charger mode |
MPPT
|
Ef?ciency |
≥97%
|
AC Charger
|
Nominal Charger Current |
35A/50A/70A/90A(According to the inverter model) 5 stages adjustable charging current
|
Over charge Protection |
Bat.V≥31.0VDC for 24V battery?Bat.V≥62.0VDC for 48V battery?beeps 0.5s every 1s & fault after 60s
|
Efficiency
|
Efficiency(Battery Mode) |
≥87%
|
Efficiency (Line Mode) |
?98%
|
Battery Voltage
|
Nominal DC input Voltage |
24/48VDC
|
Low Battery Alarm |
21VDC±0.6VDC for 24VDC
|
42VDC±1.2VDC for 48VDC
|
High DC input Alarm & Fault |
32VDC±0.6VDC for 24VDC
|
64VDC±1.2VDC for 48VDC
|
System Paramete
|
Over-Load Protection |
110%?load?150% beeps 0.5s every 1s and Fault after 60s off the output?load?150% beeps 0.5s every 1s and Fault after 20s
|
Output Short Circuit Protection |
Current limit (Fault after 10s)
|
Surge Rating(10s) |
1:3(VA)
|
Protections |
Low battery, over charging, over load, over temp
|
General Specifications
|
Storage Temperature |
?15??60?
|
Audible Noise |
60dB max
|
cooling |
Forced air, variable speed fan
|
Dimension(L*W*H) |
530*396*190mm
|
Net Weight(kg) |
29.8
|
35
|