P/No: HQ2000 – Line interactive UPS with AVR
Application:
The Line interactive UPS is in standby status with batteries being charged in normal AC time. When the power supply unexpectedly shuts down, the built-in inverter will in no time convert the battery output into AC to keep stable power supply. The UPS is generally considered high rate, low noise while running and cost-effective, mostly used in comparably stable environment with a small fluctuation of utility power and lower requirement of power supply quality.
Key Features:The UPS now is widely used in protection of PC in govemment offices, education institutes and SMEs.
v Micro controller (CPU),
v Waveform: square wave(battery mode).
v Wide AVR range.
v Overload and short circuit protection.
v UPS Auto on when AC recovery.
v Off mode charging.
v Humidity: less than 90%.
v Smart RS-232 or USB communication port with free download softwave from Internet.
v Modem/Line Surge Protection: RJ11/RJ12/RJ45.
v Overload/Over charge/Short-circuit protection.
v Low battery alarm, LED status display. Auto restart while AC recovery.
SPECIFICATIONS:
MODEL
|
HQ2000
|
Techlonogy
|
Line interactive AVR
(Automatic Voltage Regulator -AVR)
|
Nominal Capacity
|
2000VA/1200W
|
Power Factor
|
0.6
|
Input
|
Voltage Range
|
110/120 VAC or 220/230/240 VAC
67-137 VAC or 145~280VAC
|
Frequency
|
50/60Hz (Auto - Sensing)
|
Output
|
Voltage Range
|
110/120 VAC or 220/230/240 VAC ±10%
|
Frequency
|
50Hz or 60Hz ±10%
|
Output Waveform
|
Simulated Sine Wave
|
Output Connection
|
Multi perpose Socket * 3
|
Transfer time
|
6 -10 ms
|
Battery
ZLPOWER
|
Type
|
Sealed free maintenance lead acid battery
|
Capacity
|
12V,7AH *4PCS
|
Recharge Time
|
12 hrs to 90% of capacity full load discharge
|
Protection
|
Auto protect
|
Back-up time(at a PC load with 15"monitor)
|
>= 30 minutes
|
Function
|
Auto voltage output on AC mode, Auto shutoff if short circuit or overload
|
|
|
DB-9 port,communication software
|
Optional RS232, RJ11, RJ45, USB
|
Protection
|
AC mode
|
Fuse
|
Short circuit
|
AC
|
Fuse
|
Invert mode
|
Auto protect
|
Alarm
|
Alarm
|
Battery discharge
|
Alarm beeps every four seconds
|
Low battery voltage
|
Alarm beeps every second
|
Overload
|
Alarm beeps continuously
|
Indicator light
|
Auto adjust
|
Green lighting: AC mode
|
Battery Discharge
|
Red lighting: Battery mode
|
Environment
|
Operating temperature
|
0?~45???
|
Operating Humidity
|
10-90% non-condensing
|
Noise
|
|
UPS Dimension(L×W×H)mm
|
470*180*275
|
Net weight (Kgs)
|
18
|
* Product specifications are subject to change without further notice.