Application
ZLPOWER EX1-3K series high frequency online UPS is specially designed for servers, data-center critical network devices, sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, ATM and so on.
Features:
♦ Large Blue Ground LCD digital display shows Detail Real-Time UPS Status and parameters.
♦ Set output voltage, Frequency parameter and Bypass function on the display.
♦ Advanced MCU microprocessor control Technology, ensure long life reliability.
♦ Excellent Protection against over voltage, overload, over current, overcharge and so on.
♦ Input L and N lines reverse wiring detection.
♦ DC start function, input PFC revises function.
♦ Humanized bypass output adjustable.
♦ RS232 intelligent communication monitoring.
♦ AS-400 Dry contact and SNMP card remote intelligent control.
♦ Strong anti-jamming capability.
♦ Available to work with generators.
♦ Lightning, surge, short-circuit, network/fax/modem surge protection.
Model
|
EX1K
|
EX1KL
|
EX2K
|
EX2KL
|
EX3K
|
EX3KL
|
Capacity
|
VA
|
1000VA
|
1000VA
|
2000VA
|
2000VA
|
3000VA/
|
3000VA
|
Input
|
Nominal Voltage
|
110/115/120VAC or 200/220/230/240VAC
|
Voltage Range
|
60~138VAC or 115~300VAC
|
Frequency Range
|
50Hz : 46~54Hz : 60Hz; 56~64Hz
|
Phase
|
Single phase with Ground
|
Power Factor
|
≥ 0.97
|
Output
|
Voltage
|
110/115/120 (1±2%) VAC or 208/220/230/240 (1±2%) VAC
|
Frequency
|
50/60Hz (Adjustable); 50Hz AC Mode: Follow AC, Battery Mode: 50Hz (1±0.2%) 60Hz AC Mode: Follow AC, Battery Mode: 60Hz (1±0.2%)
|
Wave Form
|
Pure sine wave
|
Power Factor
|
0.8 or 0.9
|
Harmonic Distortion
|
≤ 3% THD (Linear load); ≤ 7% THD (Non-linear load)
|
Overload Capacity
|
110% ~150% maintain 30s then turn to bypass output, over 150% maintain 200ms
|
Current Crest Ratio
|
3:1
|
Connections
|
IEC320*4
|
IEC320*4
|
IEC320*6
|
IEC320*3 & Terminal block
|
IEC320*6
|
IEC320*3 & Terminal block
|
Efficiency
|
TO Battery Mode
|
83%
|
TO AC Mode
|
85%
|
Battery
|
Type
|
Sealed free maintenance lead acid battery
|
Nominal DC voltage
|
Built in batteries 12V 7.0AH
|
36Vdc
|
Built in batteries 12V 7.0AH
|
96Vdc
|
Built in batteries 12V 7.0AH
|
96Vdc
|
Quantity
|
3 PCS
|
Depend on requested back-up time
|
8 PCS
|
Depend on requested back-up time
|
8 PCS
|
Depend on requested back-up time
|
Back-up Time (Full Load)
|
≥ 7min
|
Depends on the capacity of external battery bank
|
≥ 7min
|
Depends on the capacity of external battery bank
|
≥ 6min
|
Depends on the capacity of external battery bank
|
Recharge Time
|
5 hours to 90% of capacity full discharge
|
Depends on the capacity of external battery bank
|
5 hours to 90% of capacity full discharge
|
Depends on the capacity of external battery bank
|
5 hours to 90% of capacity full discharge
|
Depends on the capacity of external battery bank
|
Charge Current (MAX)
|
1.0 A
|
5.0A / 8.0A
|
1.0 A
|
1.0 A
|
5.0A / 7.0A
|
5.0A / 8.0A
|
Charge Voltage (VDC)
|
41.1V±0.4V
|
41.1V±0.4V
|
110V±0.6V
|
110V±0.6V
|
110V±0.6V
|
110V±0.6V
|
Bypass
|
Automatic Transfer
|
On overload and UPS failure
|
Before UPS Power-on
|
Default ”ON” user adjustable to “YES”
|
Transfer Time
|
|
0ms; less than 4ms from inverter to bypass and vice versa
|
Indicators
|
LCD Display
|
UPS status, Battery capacity, loading, Fault code (LCD: I/P&O/P voltage&frequency, Battery voltage)
|
Audible Alarm
|
|
Bypass, battery mode, Battery low, Overload, Fault
|
Acoustic Noise
|
At 1 Meter Distance
|
< 45dB
|
< 50dB
|
Communications
|
Intelligent RS232 serial port
|
Software support Windows family software, Linux, Sun network operating system,IBM Aix, Compaq True64 SGI IRIX, FreeBSD, HP-UX and MAC
|
SNMP (Optional)
|
Remote control UPS through SNMP management and Internet
|
USB (Optional)
|
Windows family software and Mac OS
|
Network Surge Protection
|
|
RJ45 I/O port available for network or FAX/Telephone line/Modem
|
Environmental
|
Operating Temperature
|
0~40℃
|
Operating Humidity
|
20-90% (No condensing )
|
Weight
|
Net Weight (kgs)
|
11
|
5.5
|
26.5
|
10.5
|
27
|
11
|
UPS Dimension
|
L*W*H (mm)
|
370*145*220
|
455*195*340
|