 Product Series 
 | 
 LW 
1000 
 | 
 LW 
1500 
 | 
 LW 
2000 
 | 
 LW 
3000 
 | 
 LW 
4000 
 | 
 LW 
5000 
 | 
 LW 
6000 
 | 
| 
 General Specification 
 | 
 Input Wave form 
 | 
 Sine wave (Utility or Generator) 
 | 
| 
 Nominal voltage 
 | 
 120VAC 
 | 
 230VAC 
 | 
| 
 Low voltage trip 
 | 
 90v+4% 
 | 
 184v/154v+4% 
 | 
| 
 Low voltage reconnect 
 | 
 100v+4% 
 | 
 194v/164v+4% 
 | 
| 
 High voltage trip 
 | 
 140v+4% 
 | 
 253v+4% 
 | 
| 
 High voltage reconnect 
 | 
 135v+4% 
 | 
 243v+4% 
 | 
| 
 Max input AC voltage 
 | 
 150VAC 
 | 
 270VAC 
 | 
| 
 Nominal input frequency 
 | 
 50Hz or 60Hz (Auto detect) 
 | 
| 
 Low freq trip 
 | 
 47Hz for 50Hz, 57Hz for 60Hz 
 | 
| 
 High freq trip 
 | 
 55Hz for 50Hz, 65Hz for 60Hz 
 | 
| 
 Output wave form 
 | 
 (Bypass mode) same as input 
 | 
| 
 Overload protection 
 | 
 Circuit breaker 
 | 
| 
 Short circuit protection 
 | 
 Circuit breaker 
 | 
| 
 Transfer switch rating 
 | 
 30amp or 40amp 
 | 
| 
 Efficiency on line transfer time 
 | 
 95%+ 
 | 
| 
 Line transfer time 
 | 
 10ms Typical 
 | 
| 
 Bypass without battery connected 
 | 
 yes 
 | 
| 
 Max bypass current 
 | 
 30amp or 40amp 
 | 
| 
 Bypass overload current 
 | 
 35amp or 45amp: Alarm 
 | 
| 
 Inverter Specification Output 
 | 
 Output wave form 
 | 
 Pure sine wave 
 | 
| 
 Output continuous power watts 
 | 
 1000 
 | 
 1500 
 | 
 2000 
 | 
 3000 
 | 
 4000 
 | 
 5000 
 | 
 6000 
 | 
| 
 Output continuous power VA 
 | 
 1000 
 | 
 1500 
 | 
 2000 
 | 
 3000 
 | 
 4000 
 | 
 5000 
 | 
 6000 
 | 
| 
 Power factor 
 | 
 0.9-1.0 
 | 
| 
 Nominal output voltage rms 
 | 
 120/230VAC 
 | 
| 
 Output voltage regulation 
 | 
 10% rms 
 | 
| 
 Output frequency 
 | 
 50Hz+0.3Hz or 60Hz+0.3Hz 
 | 
| 
 Nominal efficiency 
 | 
 >88% 
 | 
| 
 Surge ratings 
 | 
 3000 
 | 
 4500 
 | 
 6000 
 | 
 9000 
 | 
 12000 
 | 
 15000 
 | 
 18000 
 | 
| 
 Short circuit protection 
 | 
 Yes, shutdown after 10ms 
 | 
| 
 Inverter Specification Input 
 | 
 Nominal input voltage 
 | 
 12V 
 | 
 24V 
 | 
 48V 
 | 
| 
 Minimum start voltage 
 | 
 10V 
 | 
 20V 
 | 
 40V 
 | 
| 
 Low battery alarm 
 | 
 10.5V 
 | 
 21V 
 | 
 42V 
 | 
| 
 Low battery trip 
 | 
 10V 
 | 
 20V 
 | 
 40V 
 | 
| 
 High voltage alram 
 | 
 16V 
 | 
 32V 
 | 
 64V 
 | 
| 
 Power saver 
 | 
 Below 25watts when enabled 
 | 
| 
 Power saver 
 | 
 Same switched on/off on remote 
 | 
| 
 Charge Mode Specification 
 | 
 Input voltage range 
 | 
 95-127VAC 
 | 
 194-243VAC/ 164-243VAC(W) 
 | 
| 
 Output voltage range 
 | 
 Dependent on battery type 
 | 
| 
 Charge current 
 | 
 35A/70A 
 | 
| 
 Batteryinitial voltage for start up 
 | 
 0-15.7v for 12v (*2 for 24v; *4 for 48v) 
 | 
| 
 Over charge protection shutdown 
 | 
 15.7v for 12v (*2 for 24v; *4 for 48v) 
 | 
| 
 Others 
 | 
 Remote control/RS232/USB 
 | 
 Yes, Optional 
 | 
| 
 Size: in mm 
 | 
 1000/2000/3000 Model: 442*218*179 
 | 
| 
 ? 
 | 
 4000/5000/6000 Model: 598*218*179 
 | 
| 
 Net weight 
 | 
 LW1000 
 | 
 LW1500 
 | 
 LW2000 
 | 
 LW3000 
 | 
 LW4000 
 | 
 LW5000 
 | 
 LW6000 
 | 
| 
 ? 
 | 
 20.00kgs 
 | 
 20.00kgs 
 | 
 20.00kgs 
 | 
 26.00kgs 
 | 
 48.00kgs 
 | 
 48.00kgs 
 | 
 48.00kgs 
 |